5.2 Servomotor and SERVOPACK Main Circuit Wire Size and Connectors

5-7

5

(3) SERVOPACK Power Supply Input Connector Kit

(a) Type

(b) Dimensional Drawings and Connector Pin Arrangement

• CN7 (Control power input connector)

Connector with cage: 721-102/026-000 (WAGO Company of Japan Ltd.)

• CN9 (Main circuit power input connector)

Connector with cage: 721-203/026-000 (WAGO Company of Japan Ltd.)

Type

Attached Connector

Connector Type

Manufacturer

JZSP-CJG9-2

CN7

Control power input connector

721-102/026-000

WAGO Company of
Japan Ltd.

CN9

Main circuit power input connector

721-203/026-000

Pin No.

Signal

Terminal Name

Item

1

C1

Control power input (+)

24/48 VDC terminal

2

C2

Control power input (

−)

DC ground terminal

Pin No.

Signal

Terminal Name

Item

1

C1

Control power input (+)

24/48 VDC terminal

2

C2

Control power input (

−)

DC ground terminal

3

FG/G

Ground terminal

Motor ground terminal

1.5

(0.06)

5

(0.20)

5

(0.20)

11.5 (0.45)

Units: mm (in)

1-pin

Latch

Coding finger

8.5

(0.33)

18 (0.71)

26.5 (1.04)

14.5 (0.57)

7.5

(0.30)

7.5

(0.30)

1.5

(0.06)

5

(0.20)

21.5 (0.85)

Units: mm (in)

1-pin

Latch

Coding finger

8.5

(0.33)

18 (0.71)

26.5 (1.04)

14.5 (0.57)