4 i/o signal connector (cn1) terminal layout, S for speed/torque control, 1) sgdj – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 129

Advertising
background image

6 Wiring

6.3.4 I/O Signal Connector (CN1) Terminal Layout

6-10

6.3.4 I/O Signal Connector (CN1) Terminal Layout

(1) SGDJ-

†††

S for Speed/Torque Control

The following diagram shows the terminal layout and the signals that are preset before shipping.

Note: 1. Do not use unused terminals for relays.

2. Connect the shield of the I/O signal cable to the connector shell.

Connect to the FG (frame ground) at the SERVOPACK-end connector.

3. The functions allocated to the following input and output signals can be changed by using the

parameters. Refer to 7.3.2 Input Circuit Signal Allocation and 7.3.3 Output Circuit Signal Allo-
cation.

• Input signals: /S-ON, /P-CON, P-OT, N-OT, /ALM-RST, /P-CL, and /N-CL
• Output signals: /TGON, /S-RDY, and /V-CMP (/COIN)
• The above output signals can be changed to /CLT, /VLT, /BK, /WARN, and /NEAR.

Pin

Num-

ber

Signal

Name

Function

1

T-REF

Torque refer-
ence input

19 SG-PG

Signal ground
for PG output
signal

2

SG

Signal
ground for
torque refer-
ence

20 PAO

PG dividing
pulse output
phase A

3

V-REF

Speed refer-
ence input

21 /PAO

PG dividing
pulse output
phase A

4

SG

Signal
ground for
speed refer-
ence input

22 PBO

PG dividing
pulse output
phase B

5

SEN

SEN signal for
absolute
encoder

23 /PBO

PG dividing
pulse output
phase B

6

SG-SEN Signal

ground for
SEN signal

24 PCO

PG dividing
pulse output
phase C

7

S-RDY

Servo ready
signal output

25 /PCO

PG dividing
pulse output
phase C

8

/V-CMP

Speed coin-
cidence out-
put

26 PSO

Absolute
encoder output
phase S

9

/TGON

TGON signal
output

27 /PSO

Absolute
encoder output
phase S

10

SG-
COM

Signal
ground-
common

28 BAT

Backup battery
input (+)

11 /P-CL

Forward current
limit ON input

29 BAT0

Backup battery
input 0 V

12

/N-CL

Reverse cur-
rent limit
ON input

30 ALO1

Alarm code
output 1

13 +24VIN

External power
supply input

31 ALO2

Alarm code
output 2

14

/S-ON

Servo ON
input

32 ALO3

Alarm code
output 3

15 /P-CON

P control input

33 AL-SG

Alarm code sig-
nal ground

16

P-OT

Forward
rotation pro-
hibited

34 ALM

Servo alarm
output

17 N-OT

Reverse rota-
tion prohibited

35 ALM-

SG

Alarm output
signal ground

18

/ALM-
RST

Alarm reset
input

36 −

Not used

Advertising