8.9 Limiting Torque

8-71

8

8.9.3 Torque Limiting Using an Analog Voltage Reference

Torque limiting by analog voltage reference limits torque by assigning a torque limit in an analog voltage to the
T-REF terminals (CN1-1 and 2) in the SGDJ-†††S SERVOPACK. This function can be used only with the
speed control in the SGDJ-†††S SERVOPACK and not with the torque control.
Refer to the following block diagram when the torque limit with an analog voltage reference is used for speed
control.

There is no polarity in the input voltage of the analog voltage reference for torque limiting. The absolute values of both +
and - voltages are input, and a torque limit value corresponding to that absolute value is applied in the forward or reverse
direction.

(1) Related Parameters

(2) Input Signals

Pn300

+
+

+

-

Pn400

T-REF

V-REF

Forward torque
limit value (Pn402)

Speed loop
gain
(Pn100)

Speed feedback

Torque limit
value

Speed
reference

Torque
reference

Reverse torque
limit value (Pn403)

Speed loop

integral

time

constant
(Pn101)

SERVOPACK

INFO

Parameter

Meaning

Pn002

n.†††1

Speed control option: Uses the T-REF terminal to be used as an external torque limit input.

When n.†††2 is set, the T-REF terminal is used for torque feed-forward input, but the functions cannot be used together.

Type

Signal

Name

Connector

Pin Number

Name

Input

T-REF

CN1-1

Torque reference input

SG

CN1-2

Signal ground for torque reference input

The torque limit input gain is set at parameter Pn400. Refer to 8.7.1 Setting Parameters.

„ Input Specifications

• Input range:

±

1 VDC to

±

10 VDC/rated torque

• Maximum allowable input voltage:

±

12 VDC