7.3 Operation in Parameter Setting Mode (Pn†††)

7-17

7

7.3 Operation in Parameter Setting Mode (Pn†††)

Functions can be selected or adjusted by setting parameters. There are two types of parameters. One type requires
value setting and the other requires function selection. These two types use different setting methods.

With value setting, a parameter is set to a value within the specified range of the parameter. With function selec-
tion, the functions allocated to each digit of the seven-segment LED panel indicator (five digits) can be selected.

7.3.1 Setting Parameters

(1) Value Setting Parameters

(a) Types of Value Setting Parameters

Refer to 10.4.2 List of Parameters.

(b) Example of Changing Value Setting Parameter

The parameter settings can be used for changing parameter data. Before changing the data, check the permit-
ted range of the parameter.

The example below shows how to change parameter Pn100 (speed loop gain) from “40” to “100.”

Step

Display after

Operation

Key

Description

1

Press the DSPL/SET Key to select the parameter setting mode.
If a parameter other than Pn100 is displayed, press the UP or
DOWN Key to select Pn100.

Note: The enabled digit blinks.

2

Press the DATA/ENTER Key. The current data of Pn100 is dis-
played.

3

Press the LEFT or RIGHT Key to select the digit to be set.

4

Press the UP or DOWN Key to change the data.
Keep pressing UP or DOWN Key until “00100” is displayed.

5

Press the DATA/ENTER Key. The value blinks and is saved.

6

Press the DATA/ENTER Key to return to the display of Pn100.
The data for the speed loop gain (Pn100) is changed from “40”
to “100.”

EXAMPLE

DSPL

SET

(DSPL/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

ENTER

(DATA/ENTER

Key)

Advertising