8.10 Control Mode Selection

8-75

8

(2) Switching Other Than Internally Set Speed Control (Pn000.1 = 9, A, or B)

Use the following signals to switch control modes. The control modes switch as shown below for each of the sig-
nal states indicated.
When changing the sequence input signal from the factory setting (Pn50A = n.†††1), allocate the /C-SEL to
an input terminal and change modes with the /C-SEL signal. In this case, input a speed reference (analog voltage
reference) for speed control, and a position reference (pulse train reference) for position control.

Type

Signal

Name

Connector

Pin Number

Setting

Pn000 Setting

n.††9†

n.††A†

n.††B†

Input

/P-CON

CN1-15
(Factory setting)

ON (low level)

Speed

Zero clamp

Inhibit

OFF (high level)

Torque

Speed

Position

(Input)

(/C-SEL)

Must be allocated

ON (low level)

Speed

Zero clamp

Inhibit

OFF (high level)

Torque

Speed

Position

The control mode can be switched with either /P-CON or /C-SEL.
When using the /C-SEL signal, the input signal must be allocated. Refer to 7.3.2 Input Circuit Signal Allocation

.