Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 313

Advertising
background image

10 Inspection, Maintenance, and Troubleshooting

10.4.2 List of Parameters

10-32

Param-

eter No.

Name

Setting Range

Units

Factory Setting

Setting

Validation

Reference

Section

†††

S †††P

Pn000

Function Selection Basic Switches

0000

0010

After

restart

0

1

0

1

2

3

4

5

6

7

8

9

A

B

0

1

Sets CCW as forward direction.

Sets CW as forward direction (Reverse Rotation Mode).

Reserved (Do not change.)

Speed control (analog reference)

Position control (pulse train reference)

Torque control (analog reference)

Internal set speed control (contact reference)

Internal set speed control (contact reference) Speed control (analog reference)

Internal set speed control (contact reference) Position control (pulse train reference)

Internal set speed control (contact reference) Torque control (analog reference)

Position control (pulse train reference) Speed control (analog reference)

Position control (pulse train reference) Torque control (analog reference)

Torque control (analog reference) Speed control (analog reference)

Speed control (analog reference) Zero clamp

Position control (pulse train reference) Position control (Inhibit)

Direction Selection
(Refer to "8.3.2 Switching the Servomotor Rotation Direction.")

Control Method Selection
(Refer to "8.2 Control Mode Selection.")

0 to F Sets SERVOPACK axis address (Function supported by PC software SigmaWin+).

Starts up as rotation type.

Reserved (Do not change)

Axis Address

Rotation Type/Linear Type Startup Selection (When the Encoder is not Connected)

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

2 and 3