7.4 Operation in Monitor Mode (Un†††)

7-27

7

(2) Sequence I/O Signal Monitor Display

The following section describes the monitor display for sequence I/O signals.

(a)

Input Signal Monitor Display

The status of input signal allocated to each input terminal is displayed:
When the input is in OFF (open) status, the top segment (LED) is lit.
when the input is in ON (short-circuited) status, the bottom segment (LED) is lit.

Refer to 7.3.2 Input Circuit Signal Allocation for the relation between input terminals and signals.

* When using SGDJ-†††P SERVOPACK for the position control mode, the SEN signal is

assigned Pin No.36.

• When /S-ON signal is ON (Servo ON at L level)

• When /S-ON signal is OFF

• When P-OT signal operates (Operates at H level)

7 6 5 4 3 2 1

Top: OFF (H level)
Bottom: ON (L level)

Number

8

Display LED

Number

Input Terminal Name

Factory Setting

1

CN1-14

/S-ON

2

CN1-15

/P-CON

3

CN1-16

P-OT

4

CN1-17

N-OT

5

CN1-18

/ALM-RST

6

CN1-11

/P-CL

7

CN1-12

/N-CL

8

CN1-5 (36)*

SEN

EXAMPLE

The bottom segment
of number 1 is lit.

7 6 5 4 3 2 1

8

7 6 5 4 3 2 1

8

The top segment of
number 1 is lit.

The top segment of
number 3 is lit.

7 6 5 4 3 2 1

8