4 servo gain adjustment functions, 1 feed-forward reference – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 265

Advertising
background image

9 Adjustments

9.4.1 Feed-forward Reference

9-14

9.4 Servo Gain Adjustment Functions

9.4.1 Feed-forward Reference

Pn109

Feed-forward

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 100

%

0

Immediately

Pn10A

Feed-forward Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 6,400

(0.00 to 64.00 ms)

0.01ms

0

Immediately

Applies feed-forward compensation in position control inside
the

SERVOPACK

. Use this parameter to shorten positioning

time. Too high value may cause the machine to vibrate. For
ordinary machines, set 80% or less in this parameter.

Position

Position

Position
reference pulse

Encoder feedback pulse

+

+ +

-

Position loop

gain Kp

Pn109

Pn10A

Differ-

ential

Advertising