2 sgdj-***p for position control mode, 2 sgdj-†††p for position control mode – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 127

Advertising
background image

6 Wiring

6.3.2 SGDJ-†††P for Position Control Mode

6-8

6.3.2 SGDJ-†††P for Position Control Mode

* 1.

: represents twisted-pair wires.

* 2. Connect a backup battery when using an absolute encoder. When connecting a battery to the host

controller, however, do not connect a backup battery.

* 3. Customers must purchase a 24 VDC power supply with double-shielded enclosure.
* 4. Enabled when using the absolute encoder.
Note: The functions allocated to the input signals SI0 to SI6 and the output signals SO1 to SO3 can be

changed by using the parameters. Refer to 7.3.2 Input Circuit Signal Allocation and 7.3.3 Output
Circuit Signal Allocation
.

SERVOPACK

19

+5 V

0 V

SEN

SG

BAT +

BAT -

ALO1

ALO2

ALO3

PBO

PCO

/PBO

PAO
/PAO

/PCO

ALM+

ALM-

FG

36

29

1

2

6

5

4

3

28

34

35

(SI0)

(SI1)

(SI2)

(SI3)

(SI4)

(SI5)

(SI6)

24

20
21

22
23

25

30

31

32

+24 V

+24VIN

3.3 k

/S-ON

/P-CON

P-OT

N-OT

/ALM-RST

/N-CL

13

15

17

16

18

11

/P-CL

12

14

∗3.

PSO
/PSO

26
27

150

PULS

CLR

/PULS

SIGN

/SIGN

CLR

/CLR

PULS

∗1.

150

150

∗4.

Servo ON

(Servo ON when ON)

Reverse run prohibited

(Prohibited when OFF)

Forward run prohibited

(Prohibited when OFF)

Alarm reset

(Reset when ON)

Reverse current limit

(Limit when ON)

Forward current limit

(Limit when ON)

SEN signal input

Backup battery
2.8 to 4.5 V

∗2.

∗2.

P control

(P control when ON)

SIGN

Position

reference

CW

Phase A

CCW

Phase B

Connect shield

to connector shell.

Connector

shell

Alarm code output

Max. operating voltage:
30 VDC

Max. operating current:
20 mA DC

PG dividing ratio output

Applicable line receiver
SN75175 manufactured

by Texas Instruments or

the equivalent corresponding

to MC3486

Servo alarm output

(OFF for an alarm)

Photocoupler output

Max. operating voltage:
30 VDC

Max. operating current:

50 mA DC

Amount of phase-S rotation

Serial data output

Applicable line receiver

SN75175 manufactured

by Texas Instruments or

the equivalent corresponding

to MC3486

/COIN

/TGON

/S-RDY

(SO1)

(SO2)

(SO3)

Positioning completed

(ON when positioning completes.)

TGON output

(ON at levels above the setting.)

Servo alarm output

(OFF for an alarm)

10

7

9

8

SG-COM

Advertising