10 Inspection, Maintenance, and Troubleshooting

10.4.2 List of Parameters

10-44

Pn50D

Input Signal Selections 4

8888

8888

After

restart

Parame-

ter No.

Name

Setting Range

Units

Factory Setting

Setting

Validation

Reference

Section

†††

S †††P

0

1

2

3

0 to F Same as /ZCLAMP

Same as /ZCLAMP

ON when CN1-14 input signal is ON (L-level).

ON when CN1-15 input signal is ON (L-level).

ON when CN1-16 input signal is ON (L-level).

ON when CN1-17 input signal is ON (L-level).

ON when CN1-18 input signal is ON (L-level).

ON when CN1-11 input signal is ON (L-level).

ON when CN1-14 input signal is OFF (H-level).

ON when CN1-15 input signal is OFF (H-level).

ON when CN1-16 input signal is OFF (H-level).

ON when CN1-17 input signal is OFF (H-level).

ON when CN1-18 input signal is OFF (H-level).

ON when CN1-11 input signal is OFF (H-level).

ON when CN1-12 input signal is OFF (H-level).

ON when CN1-12 input signal is ON (L-level).

/ZCLAMP Signal Mapping (Zero clamp when ON (L-level))

(Refer to "8.5.6 Using the Zero Clamp Function.")

/INHIBIT Signal Mapping (Reference pulse inhibit when ON (L-level))

(Refer to "8.6.7 Reference Pulse Inhibit Function (INHIBIT).")

/G-SEL Signal Mapping (Gain change when ON (L-level))

(Refer to "9.4.8 Switching Gain Settings.")

Reserved (Do not change)

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

0 to F

4

5

6

7

8

9

A

B

C

D

E

F

Sets signal OFF.

Sets signal ON.