8.5 Operating Using Speed Control with Analog Reference

8-37

8

8.5 Operating Using Speed Control with Analog Reference

8.5.1 Setting Parameters

Parameter

Description

Pn000

n.††0†

Control mode selection: Speed control (analog reference) (factory setting)

SGDJ-

†††S

Speed

x

Torque

Pn300

Speed Reference Input Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1.50 to 3000

(150 to 30.00 V/Rated speed)

0.01 V/Rated

speed

600

Immediately

Sets the analog voltage level for the speed reference (V-REF) necessary to operate the
servomotor at the rated speed.

„ EXAMPLE

Pn300=600: 6-V input is equivalent to the rated speed of the servomotor

(factory setting).

Pn300=1000: 10-V input is equivalent to the rated speed of the servomotor.
Pn300=200: 2-V input is equivalent to the rated speed of the servomotor.

Speed

Position

Torque

Reference

Reference
Voltage (V)

Speed
(min )

-1

Set this
slope.