5) holding brake electrical specifications – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 48

Advertising
background image

3.2 Ratings and Specifications of SGMAJ (3000min

-1

)

3-7

3

(5) Holding Brake Electrical Specifications

Note: The holding brake is only used to hold the load and cannot be used to stop the servomotor.

Holding

Brake Rated

Voltage

Servomotor

Model

Servomotor

Capacity

W

Holding Brake Specifications

Capacity

W

Holding

Torque

N·m (oz·in)

Coil

Resistance

Ω (at 20 °C)

Rated

Current

A (at 20

°C)

24 VDC

SGMAJ-A5

50

6

0.159

(22.5)

96

0.25

SGMAJ-A8

80

6

0.255

(36.1)

96

0.25

SGMAJ-01

100

6

0.318

(45.0)

96

0.25

SGMAJ-02

200

6.9

0.637

(338)

83.5

0.29

SGMAJ-03

300

6.9

0.955

(90.2)

83.5

0.29

Advertising