8.3 Setting Common Basic Functions

8-19

8

8.3.2 Switching the Servomotor Rotation Direction

The rotation direction of the servomotor can be switched without changing the reference pulse to the
SERVOPACK or the reference voltage polarity.
This causes the travel direction (+, -) of the shaft reverse. The output signal polarity such as encoder pulse output
and analog monitor signal from the SERVOPACK does not change.

The standard setting for “forward rotation” is counterclockwise as viewed from the drive end.

Parameter

Name

Reference

Forward Reference

Reverse Reference

Pn000

n.†††0

Standard setting
(CCW = For-
ward)
(Factory setting)

n.†††1

Reverse Rotation
Mode
(CW = Reverse)

The direction of P-OT and N-OT change. For Pn000 = n.†††0 (standard setting), counterclockwise is P-OT. For Pn000
= n.†††1 (Reverse Rotation Mode), clockwise is P-OT.

Analog monitor

Forward
(CCW)

Rotation speed

torque reference

Phase B advanced

Encoder pulse division output

PAO

PBO

Analog monitor

Phase A advanced

Encoder pulse division output

PAO

PBO

Reverse
(CW)

Analog monitor

Phase B advanced

Encoder pulse division output

PAO

PBO

Reverse
(CW)

Phase A advanced

Analog monitor

Encoder pulse division output

PAO

PBO

Forward
(CCW)