10 Inspection, Maintenance, and Troubleshooting

10.1.4 Troubleshooting for Malfunction without Alarm Display

10-14

Servomotor
Rotates With-
out Refer-
ence Input

Speed control: Speed reference input
is incorrect.

Check V-REF and SG to confirm if the con-
trol method and the input are agreed.

Correct the control mode selection parameter, or the
input correctly.

Torque control: Torque reference
input is incorrect.

Check V-REF and SG to confirm if the con-
trol method and the input are agreed.

Correct the control mode selection parameter, or the
input correctly.

Speed reference offset is error.

The SERVOPACK offset is adjusted incor-
rectly.

Adjust the SERVOPACK offset correctly.

Position control: Reference pulse
input is incorrect.

Check Pn200.0 reference pulse form or sign
+ pulse signal.

Correct the control mode selection parameter, or the
input correctly.

A SERVOPACK fault occurred.

A SERVOPACK board fault occurred.

Replace the SERVOPACK.

DB (dynamic
brake) Does
Not Operate

Improper parameter setting

Check the setting of parameter Pn001.0.

Correct the parameter setting.

DB resistor disconnected

Check if excessive moment of inertia,
motor overspeed, or DB frequently acti-
vated occurred.

Replace the SERVOPACK, and reconsider the load.

DB drive circuit fault

DB circuit parts are faulty.

Replace the SERVOPACK.

Abnormal
Noise from
Servomotor

Mounting not secured

Check if there are any loosen mounting
screws.

Tighten the mounting screws.

Check if there are misalignment of cou-
plings.

Align the couplings.

Check if there are unbalanced couplings.

Balance the couplings.

Defective bearings

Check for noise and vibration around the
bearings.

If any problems, contact your Yaskawa representative.

Vibration source on the driven
machine

Any foreign matter, damages, or deforma-
tion on the machine movable section.

Contact the machine manufacturer.

Noise interference due to incorrect
input signal wire specifications

The specifications of input signal wires
must be:
Twisted-pair or twisted-pair shielded wire
with core 0.12 mm

2

(0.0002 in

2

) min. and

tinned annealed copper twisted wire.

Use the specified input signal wires.

Noise interference due to long dis-
tance of input signal line

The wiring distance must be 3 m (9.84 ft)
max. and the impedance a few hundreds
ohm max.

Shorten the wiring distance for input signal line to the
specified value.

Noise interference due to incorrect
encoder cable specifications

The specifications of encoder cable must
be:
Twisted-pair or twisted-pair shielded wire
with core 0.12 mm

2

(0.0002 in

2

) min. and

tinned annealed copper twisted wire.

Use the specified encoder cable.

Noise interference due to long
encoder cable wiring distance

The wiring distance must be 20 m(65.6 ft)
max.

Shorten the encoder cable wiring distance to the speci-
fied value.

Noise due to damaged encoder cable

Check if the encoder cable is not damaged
or bent.

Modify the encoder cable layout.

Excessive noise to the encoder cable

Check if the encoder cable is bundled with
high-current line or near the high-current
line.

Install a surge suppressor to the encoder cable.

FG electrical potential varies by
influence of such machines on the
servomotor side as welders.

Check if the machine is correctly grounded.

Ground the machine separately from PG side FG.

SERVOPACK pulse counting error
due to noise

Check if there is noise interference on the
signal line from encoder.

Take measure against noise for the encoder wiring.

Excessive vibration and shock to the
encoder

Vibration from the machine occurred or ser-
vomotor installation is incorrect.
(Mounting surface accuracy, fixing, align-
ment, etc.)

Reduce vibration from the machine, or secure the servo-
motor installation.

Encoder fault

An encoder fault occurred.

Replace the servomotor.

Table 10.5 Troubleshooting for Malfunction without Alarm Display (cont’d)

Symptom

Cause

Inspection

Corrective Actions

: Turn OFF the servo system before executing operations.

Advertising