10.4 List of Parameters

10-33

10

Pn001

Function Selection Application Switches 1

0000

0010

After

restart

Param-

eter No.

Name

Setting Range

Units

Factory Setting

Setting

Validation

Reference

Section

†††

S †††P

0

1

2

0

1

2

Stops the motor by applying dynamic brake (DB).

Stops the motor by applying dynamic brake (DB) and then releases DB.

Makes the motor coast to a stop state without using the dynamic brake (DB).

Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).

Sets the torque of Pn406 to the maximum value, decelerate the motor to a stop, and then sets it
to servolock state.

Sets the torque of Pn406 to the maximum value, decelerates the motor to a stop, and then sets it
to coasting state.

Servo OFF or Alarm Stop Mode
(Refer to "8.3.5 Selecting the Stopping Method After Servo OFF.")

Overtravel (OT) Stop Mode
(Refer to "8.3.3 Setting the Overtravel Limit Function.")

0

1

Reserved (Do not change)

AC/DC Power Input Selection

0

1

ALO1, ALO2, and ALO3 output only alarm codes.

Warning Code Output Selection
(Refer to "8.11.2 Warning Output (/WARN).")

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Applicable to DC power input: Input DC power supply between L1 and L2

ALO1, ALO2, and ALO3 output both alarm codes and warning codes. While warning
codes are output, ALM signal output remains ON (normal state).