2 warning display – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 285

Advertising
background image

10 Inspection, Maintenance, and Troubleshooting

10.1.2 Warning Display

10-4

10.1.2 Warning Display

The relation between warning displays and warning code outputs is shown in table 10.2.

Note: Warning code is not output without setting Pn001 = n.1††† (Outputs both Alarm Codes and

Warning Codes.)

Table 10.2 Warning Displays and Outputs

Warning

Display

Warning Name

Meaning

Warning Code Output

ALO1

ALO2

ALO3

A.91

Overload

This warning occurs before the overload alarms (A.71 or
A.72) occur. If the warning is ignored and operation con-
tinues, an overload alarm may occur.

L

H

H

A.93

Absolute Encoder Battery
Voltage Lowered

This warning occurs when the absolute encoder battery
voltage is lowered. If the warning is ignored and operation
continues, an overload alarm may occur.

L

L

H