7 operating using torque control, 1 setting parameters, 2 torque reference input – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 233

Advertising
background image

8 Operation

8.7.1 Setting Parameters

8-60

8.7 Operating Using Torque Control

8.7.1 Setting Parameters

The following parameters must be set for torque control operation with analog voltage reference.

8.7.2 Torque Reference Input

By applying a torque reference determined by the analog voltage reference to the SERVOPACK, the servomotor
torque can be controlled in proportion with the input voltage.

SGDJ-

†††S

Speed

x

Torque

Parameter

Meaning

Pn000

n.

††

2

†

Control mode selection: Torque control (analog voltage reference)

Pn400

Torque Reference Input Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

10 to 100

(1.0 to 10.0 V/rated torque)

0.1V/rated torque

30

(3.0 V/rated torque)

Immediately

This sets the analog voltage level for the torque reference (T-REF) that is
necessary to operate the servomotor at the rated torque.

„ EXAMPLE

Pn400 = 30: The servomotor operates at the rated torque with 3-V input
(factory setting).
Pn400 = 1000: The servomotor operates at the rated torque with 10-V
input.
Pn400 = 200: The servomotor operates at the rated torque with 2-V input.

Speed

Position

Torque

Reference voltage (V)

Reference torque

This reference voltage is set.

Rated torque

Type

Signal

Name

Connector

Pin Number

Name

Input

T-REF

CN1-1

Torque Reference Input

SG

CN1-2

Signal Ground for Torque Reference Input

Used during torque control (analog voltage reference). (Pn000.1 = 2, 6, 9)
The torque reference gain is set in Pn400. For setting details, refer to 8.7.1 Setting Parameters.

„ Input Specifications

• Input range:

±

1 to

±10

VDC

/ra

ted torque

• Max. allowable input voltage:

±

12 VDC

• Factory setting

Pn400 = 30: Rated torque at 3 V
+3-V input: Rated torque in forward direction
+9-V input: 300% rated torque in forward direction
-0.3-V input: 10% rated torque in reverse direction
The voltage input range can be changed with parameter Pn400.

„ Input Circuit Example

Use twisted-pair wires as a countermeasure against noise.
Variable resistor example: Model 25HP-10B manufactured by Sakae
Tsushin Kogyo Co., Ltd.

Reference torque (%)

Input voltage (V)

Set the slope
with Pn400.

Factory setting

300

200

100

- 300

- 200

- 100

0

3 4

8

12

- 4

- 8

- 12

SG

T-REF

+12 V

1

2

470

2 k

SERVOPACK

1/2 W min.

CN1

Advertising