background image

8 Operation

8.5.2 Setting Input Signals

8-38

8.5.2 Setting Input Signals

(1) Speed Reference Input

Input the speed reference to the SERVOPACK using the analog voltage reference to control the servomotor speed
in proportion to the input voltage.

(2) Proportional Control Reference (/P-CON)

Type

Signal

Name

Connector Pin

Number

Name

Input

V-REF

CN1-3

Speed Reference Input

SG

CN1-4

Signal Ground for Speed Reference Input

The above inputs are used for speed control (analog voltage reference). (Pn000.1 = 0, 4, 9, or A)
Pn300 is used to set the speed reference input gain. Refer to 8.5.1 Setting Parameters.

„ Input Specifications

• Input range: ±2 VDC to ±10 VDC/rated speed
• Maximum allowable input voltage: ±12 VDC

• Setting Example

Pn300 = 600: Rated speed at

±6 V

Actual examples are shown below.

Parameter Pn300 can be used to change the voltage input range.

„ Input Circuit Example

• Always use twisted-pair wire to control noise.
• Recommended variable resistor: Model 25HP-

10B manufactured by Sakae Tsushin Kogyo Co.,
Ltd.

Connect V-REF and SG to the speed reference output terminals on
the host controller when using a host controller, such as a program-
mable controller, for position control.

Type

Signal

Name

Connector

Pin Number

Setting

Description

Input

/P-CON

CN1-15

ON (low level)

Operates the SERVOPACK with proportional control.

OFF (high level) Operates the SERVOPACK with proportional integral

control.

/P-CON signal selects either the PI (proportional integral) or P (proportional) Speed Control Mode.
Switching to P control reduces servomotor rotation and minute vibrations due to speed reference input drift.
Input reference: At 0 V, the servomotor rotation due to drift will be reduced, but servomotor rigidity (holding force) drops
when the servomotor is stopped.
Note: A parameter can be used to reallocate the input connector number for the /P-CON signal. Refer to 7.3.2 Input Circuit
Signal Allocation
.

Input voltage (V)

Factory setting

Rated motor speed

Rated motor speed

The slope is set in Pn300.

-4

-8

-12

4

8

12

Speed Reference

Input

Rotation
Direction

Motor Speed

SGMAH

Servomotor

+6 V

Forward

Rated motor speed

3000 min

Forward

(1/6) rated motor speed

(1/2) rated motor speed

Reverse

+1 V

-3 V

500 min

1500 min

-1

-1

-1

CN1

3

4

SG

V-REF

2 k

+12 V

SERVOPACK

1.8 k

Ω 1/2 W min.

SG

V-REF

CN1

4

20

21

22

23

3

/PBO

PBO

/PAO

PAO

Feedback
pulse input
terminals

Speed reference

Host controller

output terminals

SERVOPACK

: represents twisted-pair wires.

Advertising