Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 209

Advertising
background image

8 Operation

8.4.8 Multiturn Limit Setting When Multiturn Limit Disagreement (A.CC) Occurred

8-36

8.4.8 Multiturn Limit Setting When Multiturn Limit Disagreement (A.CC) Occurred

Perform the following operation using the digital operator.
This operation can only be done when the A.CC alarm is generated.

Step

Display after

Operation

Key

Description

1

Press the DSPL/SET Key to select the utility function mode.

2

Press the LEFT/RIGHT or UP/DOWN Key or the UP or DOWN Key
to set the parameter Fn013.
*The digit that can be set will blink.

3

Press the DATA/ENTER Key. The display on the left will appear.

4

Press the DSPL/SET Key. The multiturn limit setting in the absolute
encoder will be changed.
When the setting is completed, “donE” will blink for about one second.

5

About one second

later

After “donE” is displayed, “PGSEt” will be displayed again.

6

Press the DATA/ENTER Key to return to the Fn013 display of the util-
ity function mode.

7

Turn OFF the power, and then turn it ON again to make the setting valid.

DSPL

SET

(DSPL/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DSPL

SET

(DSPL/SET Key)

DATA

ENTER

(DATA/ENTER

Key)