10 Inspection, Maintenance, and Troubleshooting

10.2.1 Servomotor Inspection

10-18

10.2 Inspection and Maintenance

10.2.1 Servomotor Inspection

The AC servomotors are brushless. Simple, daily inspection is sufficient. The inspection and maintenance fre-
quencies in Table 10.6 are only guidelines. Increase or decrease the frequency to suit the operating conditions and
environment.

During inspection and maintenance, do not disassemble the servomotor. If disassembly of the servomotor is
required, contact your Yaskawa representative.

* Measure across the servomotor FG and the phase-U, phase-V, or phase-W power line.

10.2.2 SERVOPACK Inspection

For inspection and maintenance of the SERVOPACK, follow the inspection procedures in Table 10.7 at least
once every year. Other routine inspections are not required.

Table 10.6 Servomotor Inspections

Item

Frequency

Procedure

Comments

Vibration and Noise

Daily

Touch and listen.

Levels higher than normal?

Exterior

According to degree
of contamination

Clean with cloth or compressed
air.

Insulation Resistance
Measurement

At least once a year

Disconnect SERVOPACK and
test insulation resistance
at 500 V. Must exceed 10 M

Ω .

Contact your Yaskawa repre-
sentative if the insulation
resistance is below 10 M

Ω .

Replacing Oil Seal

At least once every
5,000 hours

Remove servomotor from
machine and replace oil seal.

Applies only to servomotors
with oil seals.

Overhaul

At least once every
20,000 hours or 5
years

Contact your Yaskawa represen-
tative.

The user should not disassem-
ble and clean the servomotor.

IMPORTANT

Table 10.7 SERVOPACK Inspections

Item

Frequency

Procedure

Comments

Clean Interior and
Circuit Boards

At least once a year

Check for dust, dirt, and oil
on the surfaces.

Clean with cloth or compressed air.

Loose Screws

Check for loose terminal
block and connector
screws.

Tighten any loose screws.

Defective Parts in
Unit or on
Circuit Boards

Check for discoloration,
damage, or discontinuities
due to heating.

Contact your Yaskawa representative.

Advertising