7 encoder signal output – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 217

Advertising
background image

8 Operation

8.5.7 Encoder Signal Output

8-44

8.5.7 Encoder Signal Output

Encoder feedback pulses processed inside the SERVOPACK can be output externally.

The following signals are added when using an absolute encoder.

* SG (CN1-1, 2): Connect to 0 V on the host controller.

Dividing

The dividing means that the divider converts data into the pulse density based on the pulse data of the encoder installed on
the servomotor, and outputs it. The setting unit is the number of pulses/revolution.

Type

Signal

Name

Connector

Pin Number

Name

Output

PAO

CN1-20

Encoder output phase A

/PAO

CN1-21

Encoder output phase /A

Output

PBO

CN1-22

Encoder output phase B

/PBO

CN1-23

Encoder output phase /B

Output

PCO

CN1-24

Encoder output phase C (zero-point pulse)

/PCO

CN1-25

Encoder output phase /C (zero-point pulse)

* Even in reverse rotation mode (Pn000.0 = 1), the dividing output phase form is the same as that for the standard setting

(Pn000.0 = 0).

„ Output Phase Form

PG

SERVOPACK

CN2

CN1

(Servomotor)
Encoder

Host controller

These outputs explained here.

Phase A (PAO)

Phase B (PBO)

Phase C (PCO)

Serial data

Frequency
dividing
circuit

*

Phase A

Phase B

Phase C

90˚

t

Phase A

Phase B

Phase C

90˚

t

Forward rotation (phase B leads by 90˚) Reverse rotation (phase A leads by 90˚

Type

Signal

Name

Connector

Pin Number

Name

Input

SEN

CN1-5

SEN Signal Input

SG

CN1-6

Signal Ground

BAT (+)

CN1-28

Battery (+)

BAT (-)

CN1-29

Battery (-)

Output

SG

CN1-10

Signal Ground

TERMS