1) related parameters, 2) input signals – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 242

Advertising
background image

8.9 Limiting Torque

8-69

8

8.9.2 External Torque Limit (Output Torque Limiting by Input Signals)

This function allows the torque to be limited at specific times during machine operation, for example, during
press stops and hold operations for robot workpieces.
An input signal is used to enable the torque limits previously set in parameters.

(1) Related Parameters

Note: The setting unit is a percentage of rated torque (i.e., the rated torque is 100%).

(2) Input Signals

Pn404

Forward External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately

Pn405

Reverse External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately

Speed

Position

Torque

Speed

Position

Torque

Type Signal

Name

Connector Pin

Number

Setting

Meaning

Limit Value

Input /P-CL

CN1-11
(Factory Setting)

ON (low level)

Forward external torque limit
ON

The value set in Pn402 or
Pn404 (whichever is smaller)

OFF (high level)

Forward external torque limit
OFF

Pn402

Input /N-CL

CN1-12
(Factory Setting)

ON (low level)

Reverse external torque limit
ON

The value set in Pn403 or
Pn405 (whichever is smaller)

OFF (high level)

Reverse external torque limit
OFF

Pn403

When using this function, make sure that there are no other signals allocated to the same terminals as /P-CL and /N-CL.
When multiple signals are allocated to the same terminal, the signals are handled with OR logic, which affects the ON/OFF
state of the other signals. Refer to 7.3.2 Input Circuit Signal Allocation

.