4 status display, 1) bit data and meanings – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 149

Advertising
background image

7.1 Functions on Digital Operator

7-5

7

7.1.4 Status Display

(1) Bit Data and Meanings

Bit data

Code

c

d

e

f

g

h i

Item

SGDJ-†††S

SGDJ-†††P

Bit Data

Meaning

Bit Data

Meaning

c

Control
Power ON

Lit when SERVOPACK control power is
ON.

Control
Power ON

Lit when SERVOPACK control power sup-
ply is ON.

d

Baseblock

Lit for baseblock. Not lit when servo is ON. Baseblock

Lit for baseblock. Not lit when servo is ON.

e

Speed
Coincidence
(/V-CMP)

Lit when the difference between the motor
speed and reference speed is the same as or
less than the value set in Pn503. (Factory
setting is 10 min

-1

.)

∗ Always lit in torque control mode.

Positioning
Completion
(/COIN)

Lit if error between position reference and
actual motor position is below preset value.
Not lit if error between position reference
and actual motor position exceeds preset
value.
Preset value: Set in Pn500 (Factory setting
is 7 pulses.)

f

Rotation
Detection
(/TGON)

Lit if motor speed exceeds preset value.
Not lit if motor speed is below preset value.
Preset value: Set in Pn502 (Factory setting
is 20 min

-1

.)

Rotation
Detection
(/TGON)

Lit if motor speed exceeds preset value.
Not lit if motor speed is below preset value.
Preset value: Set in Pn502 (Factory setting
is 20 min

-1

.)

g

Speed
Reference
Input

Lit if input speed reference exceeds preset
value.
Not lit if input speed reference is below pre-
set value.
Preset value: Set in Pn502 (Factory setting
is 20 min

-1

.)

Reference
Pulse Input

Lit if reference pulse is input.
Not lit if no reference pulse is input.

h

Torque
Reference
Input

Lit if input torque reference exceeds preset
value.
Not lit if input torque reference is below
preset value.
Preset value: 10% of rated torque

Error Counter
Clear Signal
Input

Lit when error counter clear signal is input.
Not lit when error counter clear signal is not
input.

i

Power Ready

Lit when main circuit power supply is ON
and normal.
Not lit when main circuit power supply
power is OFF.

Power Ready

Lit when main circuit power supply is ON
and normal.
Not lit when main circuit power supply
power is OFF.

Advertising