1 trial operation – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 177

Advertising
background image

8 Operation

8-4

8.1 Trial Operation

Make sure that all wiring has been completed prior to trial operation.
Perform the following three types of trial operation in order. Instructions are given for SGDJ-†††S speed con-

trol mode and SGDJ-†††P position control mode. Unless otherwise specified, the standard parameters for
speed control mode (factory setting) are used.

(1)Trial Operation for Servomotor without Load (Refer to 8.1.1.)

„ Purpose

The servomotor is operated without connecting the shaft to
the machine in order to confirm that the following wiring is
correct.

• Power supply circuit wiring
• Motor wiring
• Encoder wiring
• Motor’s rotation direction and motor speed

(2)Trial Operation for Servomotor with Host Reference (Refer to 8.1.2.)

„ Purpose

The servomotor is operated without connecting the shaft to
the machine in order to confirm that the following wiring is
correct.

• I/O signal wiring between the SERVOPACK and the host

controller.

• Motor’s rotation direction, motor speed, and number of

rotations

• Check the operation of the brake, overtravel, and other pro-

tective functions.

(3)Trial Operation for the Servomotor and Machine Combined (Refer to 8.1.3.)

„ Purpose

The servomotor is connected to the machine and trial opera-
tion is performed. The SERVOPACK is adjusted to match the
machine characteristics.

• The servomotor’s rotation direction, motor speed, and

machine travel distance.

• Set the necessary parameters.

To power
supply

Secure the motor flange to
the machine, but do not
connect the motor shaft to
the load shaft.

CN1

Secure the motor flange to
the machine, but do not
connect the motor shaft to
the load shaft.

To power
supply

CN1

To host controller

Secure the motor flange to the
machine, and use a coupling to
connect the motor shaft to the
load shaft.

To host controller

To power
supply

CN1

Advertising