9.3 Manual Tuning

9-11

9

9.3 Manual Tuning

9.3.1 Explanation of Servo Gain

The block diagram for position control is as follows:

To adjust the servo gain manually, understand the configuration and characteristics of the SERVOPACK and
adjust the servo gain parameters one by one. If one parameter is changed, it is almost always necessary to adjust
the other parameters. It will also be necessary to make preparations such as setting up a measuring instrument to
monitor the output waveform from the analog monitor.
The SERVOPACK has three feedback loops (i.e., position loop, speed loop, and current loop). The innermost
loop must have the highest response and the middle loop must have higher response than the outermost. If this
principle is not followed, it will result in vibration or responsiveness decreases.
The SERVOPACK is designed to ensure that the current loop has good response performance. The user need to
adjust only position loop gain and speed loop gain.

Encoder

Position control loop (SGDJ-†††P)

Speed control loop (SGDJ-†††S)

Speed

Speed pattern

Time

Move
reference

Error
counter

Position
loop
gain

Kp

Speed
control
section

Kv

Ti

+
-

Current
control
section

Electric
power
converting

Servomotor

M

PG

Position loop

SERVOPACK

Host controller

(provided by user)

Kp Position Loop Gain (Pn102
Kv Speed Loop Gain Pn100
Ti

Speed Loop Integral Time

Constant (Pn101)

Tf Torque Reference Filter Time
Constant (Pn401)

+
-

+
-

Speed
reference

Speed loop

Current loop

Tf