Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 281

Advertising
background image

9 Adjustments

9.5.2 Manual Zero Adjustment and Gain Adjustment of Analog Monitor Output (Fn00C, Fn00D)

9-30

(2) Manual Gain Adjustment of Analog Monitor Output (Fn00D)

Follow the procedure below to execute the manual gain adjustment of analog monitor output.

Step Display after Operation

Key

Description

1

Press the DSPL/SET Key to select the utility function mode.

2

Press the LEFT/RIGHT Key or the UP/DOWN Key to set the
parameter Fn00D.

3

Press the DATA/ENTER Key, and “Ch1_G” will be displayed.

4

Press the DSPL/SET Key, and the monitor output for the two
channels will be displayed alternately.

5

Press the LEFT or RIGHT Key to display the analog monitor
gain constant. Pressing the LEFT or RIGHT Key again will
return to “Ch1_G” and “Ch2_G”.

6

Press the UP or DOWN Key to adjust the gain confirming the
output waveform of the analog monitor output with the measur-
ing device.

7

Press the DATA/ENTER Key to return to the utility function
mode display Fn00D.

DSPL

SET

(DSPL/SET Key)

DATA

ENTER

(DATA/ENTER Key)

Displayed
alternately

DSPL

SET

(DSPL/SET Key)

Displayed
alternately

DATA

ENTER

(DATA/ENTER Key)

Advertising