9 Adjustments
9.5.2 Manual Zero Adjustment and Gain Adjustment of Analog Monitor Output (Fn00C, Fn00D)
9-30
(2) Manual Gain Adjustment of Analog Monitor Output (Fn00D)
Follow the procedure below to execute the manual gain adjustment of analog monitor output.
Step Display after Operation
Key
Description
1
Press the DSPL/SET Key to select the utility function mode.
2
Press the LEFT/RIGHT Key or the UP/DOWN Key to set the
parameter Fn00D.
3
Press the DATA/ENTER Key, and “Ch1_G” will be displayed.
4
Press the DSPL/SET Key, and the monitor output for the two
channels will be displayed alternately.
5
Press the LEFT or RIGHT Key to display the analog monitor
gain constant. Pressing the LEFT or RIGHT Key again will
return to “Ch1_G” and “Ch2_G”.
6
Press the UP or DOWN Key to adjust the gain confirming the
output waveform of the analog monitor output with the measur-
ing device.
7
Press the DATA/ENTER Key to return to the utility function
mode display Fn00D.
DSPL
SET
(DSPL/SET Key)
DATA
ENTER
(DATA/ENTER Key)
Displayed
alternately
DSPL
SET
(DSPL/SET Key)
Displayed
alternately
DATA
ENTER
(DATA/ENTER Key)