2 online autotuning procedure, Warning – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 257

Advertising
background image

9 Adjustments

9.2.2 Online Autotuning Procedure

9-6

9.2.2 Online Autotuning Procedure

• Do not perform extreme adjustment or setting changes causing unstable servo operation.

Failure to observe this warning may result in injury and damages to the machine.

• Adjust the gains slowly while confirming motor operation.

WARNING

Start

Operate with factory setting.

(Set Pn110.0 = 0.)

Operation OK?

Load moment of

inertia varies?

Operation OK?

Continuous online autotuning.

(Set Pn110.0 = 1.)

Ajust the machine rigidity setting.

(Set at Fn001.)

Operation OK?

Operation OK?

Do not perform online autotuning.
(Set Pn110.0 = 2.)

Adjust the friction compensation.

(Set Pn110.2.)

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

End

Write the result of autotuning
in the parameter.
The result will be used as the
default value for next autotuning.
(Utility function Fn007)

Advertising