6 Wiring

6.3.5 I/O Signal (CN1) Names and Functions

6-12

6.3.5 I/O Signal (CN1) Names and Functions

(1) Input Signals

Signal Name

SGDJ-

Function

Refer-

ence

†††

S

†††

P

Common

/S-ON

14

14

Servo ON: Turns ON the servomotor when the gate block in the inverter is
released.

8.3.1

/P-CON

15

15

Function selected by parameter.

Proportional
control reference

Switches the speed control loop from PI (proportional/
integral) to P (proportional) control when ON.

9.4.3

Direction refer-
ence

With the internal set speed selected: Switch the rotation
direction.

8.8.2

Control mode
switching

8.10.1
8.10.2

Zero-clamp ref-
erence

Speed control with zero-clamp function: Reference
speed is zero when ON.

8.5.6

Reference pulse
block

Position control with reference pulse stop: Stops refer-
ence pulse input when ON.

8.6.7

P-OT
N-OT

16
17

16
17

Forward run
prohibited
Reverse run
prohibited

Overtravel prohibited: Stops servomotor when movable
part travels beyond the allowable range of motion.

8.3.3

/P-CL
/N-CL

11
12

11
12

Function selected by parameter.

Forward exter-
nal torque limit
ON
Reverse external
torque limit ON

Current limit function enabled when ON.

8.9.2

Internal speed
switching

With the internal set speed selected: Switches the
internal speed settings.

8.8

/ALM-RST

18

18

Alarm reset: Releases the servo alarm state.

8.11.1

+24VIN

13

13

Control power supply input for sequence signals: Users must provide the
+24 V
power supply.
Allowable voltage fluctuation range: 11 to 25 V

6.3.6

SEN

5 (6)

36 (19)

Initial data request signal when using an absolute encoder.

8.4.1

BAT (+)
BAT (-)

28
29

28
29

Connecting pin for the absolute encoder backup battery.
Do not connect when a battery is connected to the host controller.

8.4.1

6.2

Speed

V-REF

3 (4)

Speed reference speed input:

±2 to ±10 V/rated motor speed (Input gain can

be
modified using a parameter.)

8.5.2

Torque

T-REF

1 (2)

Torque reference input:

±1 to ±10 V/rated motor torque (Input gain can be

modified using a parameter.)

8.7.2

Position

PULS
/PULS
SIGN
/SIGN




1
2
3
4

Reference pulse
input
for only line
driver

Input mode is set from the following pulses.

• Sign + pulse string
• CCW/CW pulse
• Two-phase pulse (90

° phase differential)

8.6.1

CLR
/CLR


5
6

Positional error pulse clear input: Clears the positional error pulse during
position control.

8.6.1

Position

speed

Position

torque

Torque

speed

Enables control mode switching.