2 molded-case circuit breaker and fuse capacity – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 39

Advertising
background image

2.5 Selecting Peripheral Devices

2-13

2

2.5.2 Molded-case Circuit Breaker and Fuse Capacity

Note: 1. Connect the fuse or the molded-case circuit breaker to the DC side on the control power supply.

2. Select a fuse and a molded-case circuit breaker that are certified by the UL and the CSA and have CE

Marking.

d

Digital Operator

JUSP-OP02A-2

With connection cable (1 m (3.28 ft))

5.6.2

e

Connection Cable for Digital Op-
erator

1m
(3.28 ft)

JZSP-CMS00-1

Only required when using Σ series
Digital Operator JUSP-OP02A-1.

1.5m
(4.92 ft)

JZSP-CMS00-2

2 m
(6.56 ft)

JZSP-CMS00-3

f

Connection Cable for Personal
Computer

2 m
(6.56 ft)

JZSP-CMS01

D-Sub 25-pin (For PC98)

5.6.1

2 m
(6.56 ft)

JZSP-CMS02

D-Sub 9-pin (For DOS/V)

2 m
(6.56 ft)

JZSP-CMS03

Half-pitch 14-pin (For PC 98)

g

Analog Monitor Cable

1 m
(3.28 ft)

JZSP-CA01 or
DE9404559

5.6.3

h

Battery for Absolute Encoder

ER6VC3

To connect to a host controller (pro-
vided by a customer)
3.6 V 2000 mAh,
manufactured by Toshiba Battery
Co., Ltd.

5.6.8

(cont’d)

Name

Length

Type

Specifications

Refer-

ence

CN3

Operator 

end

SERVOPACK 

end

CN3

Personal

computer end

SERVOPACK

end

Personal

computer end

SERVOPACK

end

Personal

computer end

SERVOPACK

end

CN5

SERVOPACK end

Monitor end

CN8

SERVOPACK

model

Voltage

Capacity

(W)

Power Supply Capacity per

SERVOPACK (kVA)

Current Capacity of the Fuse and the

Molded-case Circuit Breaker

Continuous

Rating (W)

Momentary

Rating (W)

Power Supply

100 VAC (Arms)

Power Supply

200 VAC (Arms)

SGDJ-A5C

24 VDC

50

96.6

220

15

7.5

SGDJ-A8C

80

144

320

20

10

SGDJ-A5E

48 VDC

50

92.1

210

15

7.5

SGDJ-01E

100

170

380

22

11

SGDJ-02E

200

322

700

40

20

SGDJ-03E

300

467

1000

60

30

Advertising