8 Operation

8.9.4 Torque Limiting Using an External Torque Limit and Analog Voltage Reference

8-72

8.9.4 Torque Limiting Using an External Torque Limit and Analog Voltage Reference

This function can be used to combine torque limiting by an external input signal and by analog voltage reference
and can be used only for SGDJ-†††S SERVOPACK. Because the torque limit by analog voltage reference is
input from T-REF (CN1-1, 2), this function cannot be used during torque control. Use /P-CL (CN1-11) or /N-CL
(CN1-12) for torque limiting by external input signal.

When /P-CL (or /N-CL) is ON, either the torque limit by analog voltage reference or the setting in Pn404 (or
Pn405) will be applied as the torque limit, whichever is smaller.

(1) Related Parameters

* The setting unit is a percentage of rated torque (i.e., the rated torque is 100%).

Torque limit
value

Speed
reference

Pn300

+
+

+

-

Pn400

T-REF

V-REF

Pn404

( /P-CL:ON )

Forward torque
limit value (Pn402)

Pn405

( /N-CL : ON)

(Pn100)

Speed loop

integral

time

constant
(Pn101)

Speed loop
gain

Speed feedback

Torque
reference

Reverse torque
limit value (

Pn403)

/N-CL

/P-CL

SERVOPACK

Parameter

Meaning

Pn002

n.†††3

Speed control option: When /P-CL or /N-CL is enabled, the T-REF terminal is used as the
external torque limit input.

When n.†††2 is set, T-REF is used for torque feed-forward input, but the functions cannot be used together.

Pn404

Forward External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately

Pn405

Reverse External Torque Limit

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 800

%

100

Immediately