4 SERVOPACK Specifications and Dimensional Drawings

4.1.2 SERVOPACK Ratings and Specifications 2

4-4

* 1. Use the SERVOPACK within the ambient temperature range. When enclosed in a control panel, internal tem-

peratures must not exceed the ambient temperature range.

* 2. Speed regulation is defined as follows:

The motor speed may change due to voltage variations or amplifier drift and changes in processing resistance
due to temperature variation. The ratio of speed changes to the rated speed represent speed regulation due to
voltage and temperature variations.

* 3. Forward is clockwise viewed from the non-load side of the servomotor. (Counterclockwise viewed from the

load and shaft end)

I/O
Signals

Position Output

Form

Phase-A, -B, -C line driver
Phase-S line driver (only with an absolute encoder)

Applicable Applicable

Frequency Dividing
Ratio

Any

Applicable Applicable

Sequence Input

Signal allocation can
be modified.

Servo ON, P control (or Control mode switching, for-
ward/reverse motor rotation by internal speed setting,
zero clamping, reference pulse prohibited), forward run
prohibited (P-OT), reverse run prohibited (N-OT), alarm
reset, forward current limit, and reverse current limit (or
internal speed selection)

Applicable Applicable

Sequence Output

Fixed Output

Servo alarm, 3-bit alarm codes

Applicable Applicable

Signal allocation can
be modified.

Positioning completed (speed coincidence), during ser-
vomotor rotation, servo ready, during current limiting,
during speed limiting, brake released, warning, selecting
three of the NEAR signals.

Applicable Applicable

Internal
Func-
tions

Dynamic Brake

Operated at main power OFF, servo alarm, servo OFF or
overtravel.

Applicable Applicable

Overtravel Stop

Dynamic brake stop at P-OT or N-OT, deceleration to a
stop, or coast to a stop

Applicable Applicable

Electronic Gear

0.01

≤ B/A ≤ 100

N/A

Applicable

Protection

Overcurrent, overvoltage, overload, regeneration error,
main circuit detection section error, heat sink over-
heated, no power supply, overflow, overspeed, encoder
error, overrun, CPU error, parameter error.

Applicable Applicable

LED Display

Charge, Power

Applicable Applicable

CN5 Analog Monitoring

Analog monitor connector built in for monitoring speed,
torque and other reference signals.
Speed: 1 V/1000 min

-1

Torque: 1 V/100% of rated torque
Position error pulses: 0.05 V/1 reference units or 0.05 V/

100 reference units

Applicable Applicable

Communications

Connected Devices

Digital Operator (hand-held model), RS-422A port such
as for a personal computer (RS-232C ports under certain
conditions)

Applicable Applicable

1:N Communications

Up to N = 14 for RS-422A ports

Applicable Applicable

Axis Address Setting

Set with parameters.

Applicable Applicable

Functions

Status display, parameter setting, monitor display, alarm
trace-back display, JOG and autotuning operations,
speed, torque reference signal and other drawing func-
tions.

Applicable Applicable

Others

Reverse rotation connection, zero-point search, auto-
matic servomotor ID.

Applicable Applicable

(cont’d)

Item

Ratings and Specifications

SGDJ-

†††

S

†††

P

Speed reguration

=

No-load motor speed – Total load motor speed

Rated motor speed

× 100%