1.2 Product Part Names

1-5

1

1.2.2 SERVOPACKs

CN9 Main circuit power 
supply terminals and ground terminals

Used for main circuit power supply input.
Refer to 6.1 Wiring Main Circuit.

Used for control power supply input.
Refer to 6.1 Wiring Main Circuit.

CN7 Control power supply terminals

CN8 Servomotor terminals and ground terminals

Connects to the servomotor power line.
Refer to 6.1 Wiring Main Circuit.

Ready indicator

Green lights: Control power supply and main circuit 

current can be turned ON, and servomotors 
can be operated.

Red lights: Cannot be operated. (when alarms occurs.)

CN5 Analog monitor connector

Used to monitor motor speed, torque
reference, and other values through
a special cable.
Refer to 5.6.3 Cables for Analog Monitor or
9.5 Analog Monitor.

Refer to 5.6.1 Cables for Connecting Personal 
Computer
 and 5.6.2 Digital Operator.

CN3 Connector for personal computer monitoring
and digital operator

Used to communicate with a personal computer 
or to connect a digital operator.

CN1 I/O signal connector

Used for reference input signals and
sequence I/O signals.
Refer to 6.3 Examples of I/O Signal Connections.

Nameplate (side view)

Indicates the SERVOPACK model and ratings.
Refer to 1.1.3 SERVOPACKs.

CN4 Encoder connector

Connects to the encoder in the servomotor.
Refer to 6.2 Wiring Encoders.