10.4 List of Parameters

10-47

10

10.4.3 Monitor Modes

The following list shows monitor modes available.

Parameter

No.

Content of Display

Unit

Un000

Actual motor speed

min

-1

Un001

Input speed reference (Enabled only when speed control mode.)

min

-1

Un002

Internal torque reference (Value for rated torque)

%

Un003

Rotation angle 1 (Number of pulses from the zero point:16-bit decimal code)

pulse

Un004

Rotation angle 2 (Angle from the zero point (electrical angle))

deg

Un005

Input signal monitor

Un006

Output signal monitor

Un007

Input reference pulse speed (displayed only in position control mode)

min

-1

Un008

Error counter value (amount of position error) (displayed only in position control mode)

reference

unit

Un009

Accumulated load rate (Value for the rated torque as 100%: Displays effective torque in 10 s
cycle.)

%

Un00A

Reserved

Un00B

Power consumed by DB resistance
(Value for the processable power when dynamic brake is applied as 100%: Displays DB power
consumption in 10 s cycle.)

%

Un00C

Input reference pulse counter (hexadecimal code)
(displayed only in position control mode)

Un00D

Feedback pulse counter (hexadecimal code)