1 related parameters, 1) pn003: function selections – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual

Page 278

Advertising
background image

9.5 Analog Monitor

9-27

9

9.5.1 Related Parameters

The following signals can be monitored.

(1) Pn003: Function Selections

* When using speed control or torque control, the position error monitor signal is not specified.

The analog monitor output voltage is ±5 V (maximum). The output will be limited to ±5 V even if this value is exceeded
in the above calculations.

Parameter

Function

Monitor 1

Monitor 2

Monitor Signal

Observation Gain

Remarks

Pn003

n.†††0 n.††0†

Motor speed

1 V / 1000 min

-1

Factory setting for Monitor 2

n.†††1 n.††1†

Speed reference

1 V / 1000 min

-1

n.†††2 n.††2†

Internal torque reference

1 V / 100% rated torque

Factory setting for Monitor 1

n.†††3 n.††3†

Position error

0.05 V / 1 reference unit

n.†††4 n.††4†

Position error

0.05 V / 100 reference units

n.†††5 n.††5†

Position reference speed
(converted to motor speed)

1 V / 1000 min

-1

n.†††6 n.††6†

Motor speed

1 V / 250 min

-1

n.†††7 n.††7†

Motor speed

1 V / 125 min

-1

n.†††8 n.††8†

Reserved. Do not set.

n.†††9 n.††9†

n.†††A n.††A†

n.†††B n.††B†

n.†††C n.††C†

n.†††D n.††D†

n.†††E n.††E†

n.†††F n.††F†

INFO