1 related parameters, 1) pn003: function selections – Yaskawa Sigma II Series DC Power Input SGMAJ User Manual
Page 278

9.5 Analog Monitor
9-27
9
9.5.1 Related Parameters
The following signals can be monitored.
(1) Pn003: Function Selections
* When using speed control or torque control, the position error monitor signal is not specified.
The analog monitor output voltage is ±5 V (maximum). The output will be limited to ±5 V even if this value is exceeded
in the above calculations.
Parameter
Function
Monitor 1
Monitor 2
Monitor Signal
Observation Gain
Remarks
Pn003
n.0 n.0
Motor speed
1 V / 1000 min
-1
Factory setting for Monitor 2
n.1 n.1
Speed reference
1 V / 1000 min
-1
−
n.2 n.2
Internal torque reference
1 V / 100% rated torque
Factory setting for Monitor 1
n.3 n.3
Position error
∗
0.05 V / 1 reference unit
−
n.4 n.4
Position error
∗
0.05 V / 100 reference units
−
n.5 n.5
Position reference speed
(converted to motor speed)
1 V / 1000 min
-1
−
n.6 n.6
Motor speed
1 V / 250 min
-1
−
n.7 n.7
Motor speed
1 V / 125 min
-1
−
n.8 n.8
Reserved. Do not set.
−
−
n.9 n.9
−
n.A n.A
−
n.B n.B
−
n.C n.C
−
n.D n.D
−
n.E n.E
−
n.F n.F
−