Table 6.4

gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is important

to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the HOA keypad, and the fault contact

DO-10 triggers. An alarm is present if the ALM LED blinks and the fault code on the HOA keypad flashes.

Refer to Minor

Faults and Alarms on page 223

for a list of alarm codes.

Table 6.4 Fault Displays

HOA

Keypad

Display

Name

Page

bAT

HOA Keypad Battery Voltage Low

224

bUS

Option Communication Error

224

CE

MEMOBUS/Modbus Communication Error

224

CoF

Current Offset Fault

224

CPF00,

CPF01

<1>

Control Circuit Error

225

CPF02

A/D Conversion Error

225

CPF03

Control Board Connection Error

225

CPF06

EEPROM Memory Data Error

225

CPF07,

CPF08

Terminal Board Connection Error

225

CPF20,

CPF21

<2>

Control Circuit Error

225

CPF22

Hybrid IC Error

226

CPF23

Control Board Connection Error

226

CPF24

Drive Unit Signal Fault

226

EF0

Option Card External Fault

226

Err

EEPROM Write Error

226

FAn

Internal Fan Fault

226

Fn1

External Fan Fault

230

FB01

Safety Open

227

FB02

BAS Interlock Open Time Out

227

FB03

External Fault Bypass (EFB)

227

FB05

Motor Overload

227

FB06

External Motor 1 Overload

228

FB07

External Motor 2 Overload

228

FB08

Phase Loss Brownout

228

FB09

Phase Loss Blackout

228

FB10

No Drive Comms

229

FB11

Bypass Board Hardware Error

229

FB12

Option Board Comms

229

FB13

Loss of Load

229

FB14

Serial Communications Fault

229

HOA

Keypad

Display

Name

Page

FB15

<3>

Input Phase Loss

230

FB16

<3>

Input Phase Rotation

230

FbH

Excessive PI Feedback

230

FbL

PI Feedback Loss

230

GF

Ground Fault

230

LF

Output Phase Loss

231

LF2

Current Imbalance

231

nSE

Node Setup Error

231

oC

Overcurrent

231

oFA00

Option Card Connection Error (CN5)

232

oH

Heatsink Overheat

232

oH1

Heatsink Overheat

232

oH3

Motor Overheat Alarm (PTC input)

233

oH4

Motor Overheat Fault (PTC input)

233

oL1

Motor Overload

233

oL2

Drive Overload

234

oL3

Overtorque Detection 1

234

oL7

High Slip Braking oL

234

oPr

Operator Connection Fault

235

ov

Overvoltage

235

ov2

Overvoltage 2

235

PF

Input Phase Loss

235

SEr

Too Many Speed Search Restarts

236

STo

Pull-Out Detection

236

TdE

Time Data Error

236

TIM

Time Not Set

236

UL3

Undertorque Detection 1

236

UL6

Motor Underload

237

Uv1

Undervoltage

237

Uv2

Control Power Supply Undervoltage

237

Uv3

Soft Charge Circuit Fault

237

voF

Output Voltage Detection Fault

238

<1> Displayed as CPF00 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show

CPF01.

<2> Displayed as CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show

CPF21.

<3> Available in bypass controller software versions VST800298 and later.

6.3 Drive Alarms, Faults, and Errors

222

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

Advertising