N: special adjustment, N1: hunting prevention, B.10 n: special adjustment – Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 327

Advertising
background image

B.10 n: Special Adjustment

The n parameters adjust more advanced performance characteristics such as Hunting Prevention, speed feedback detection,

High Slip Braking, and Online Tuning for motor line-to-line resistance.

u

n1: Hunting Prevention

No.

(Addr.

Hex)

Name

Description

Values

Page

n1-01

(580)

Hunting Prevention

Selection

Hunt Prev Select

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Default: 1

Range: 0, 1

181

n1-02

(581)

Hunting Prevention Gain

Setting

Hunt Prev Gain

If the motor vibrates while lightly loaded, increase the gain by 0.1 until

vibration ceases. If the motor stalls, decrease the gain by 0.1 until the stalling

ceases.

Default: 1.00

Min.: 0.00

Max.: 2.50

181

u

n3: High Slip Braking (HSB) and Overexcitation Braking

No.

(Addr.

Hex)

Name

Description

Values

Page

n3-04

(58B)

High-Slip Braking Overload

Time

HSB OL Time

Sets the time required for an HSB overload fault (oL7) to occur when the drive

output frequency does not change during an HSB stop. This parameter does

not typically require adjustment.

Default: 40 s

Min.: 30

Max.: 1200

181

n3-13

(531)

Overexcitation Deceleration

Gain

Hflux Brake Gain

Sets the gain applied to the V/f pattern during Overexcitation Deceleration

(L3-04 = 4).

Default: 1.10

Min.: 1.00

Max.: 1.40

182

B.10 n: Special Adjustment

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

327

B

Parameter List

Advertising