Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 268

Advertising
background image

n

Alarm Outputs for Maintenance Monitors

An output can be set up to inform the user when a specific components has neared its expected performance life.
When one of multi-function digital output terminals has been assigned the maintenance monitor function (H2-oo = 2F

<1>

),

the terminal will close when the cooling fan, DC bus capacitors, or DC bus pre-charge relay reach 90% of the expected

performance life, or when the IGBTs have reached 50% of their expected performance life. Additionally the HOA keypad

will display an alarm like shown in

Table 7.5

to indicate the specific components that may need maintenance.

<1> Details on this function can be found in the standard Z1000 Programming Manual (SIEPC71061645) at

www.yaskawa.com.

Table 7.5 Maintenance Alarms

HOA Keypad Alarm Display

Function

Corrective Action

LT-1

The cooling fans have reached 90% of their designated

life time.

Replace the cooling fan.

LT-2

The DC bus capacitors have reached 90% of their

designated life time.

Contact a Yaskawa representative or the

nearest Yaskawa sales office on

possible drive replacement.

LT-3

The DC bus charge circuit has reached 90% of its

designated life time.

Contact a Yaskawa representative or the

nearest Yaskawa sales office on

possible drive replacement.

7.3 Periodic Maintenance

268

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual