B.15 Defaults by Drive Model

The following tables show parameters and default settings that change with the drive model selection (o2-04).

Table B.4 208 V Default Settings by Model Selection

No.

Name

Unit

Default Settings

Bypass Model Z1B1

D002

D003

D004

D007

D010

D016

D024

D031

D046

D059

D075

o2-04

Drive Model Selection

Hex.

66

68

6A

6B

6D

6E

6F

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

100

b3-06

Output Current 1 during Speed Search

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Current Control Gain during Speed Search

(Speed Estimation Type)

0.50

0.50

0.50

0.50

0.50

0.50

0.50

b3-11

Speed Search Method Switching Level (Speed

Estimation Type)

5.0

5.0

5.0

5.0

5.0

5.0

5.0

C6-02

Carrier Frequency Selection

2

2

2

2

2

2

2

E2-01

Motor Rated Current

A

10.60

16.70

24.20

30.80

46.2

59.4

74.8

E2-03

Motor No-Load Current

A

3.00

4.50

5.10

8.00

11.2

15.2

15.7

L2-03

Momentary Power Loss Minimum Baseblock

Time

s

0.5

0.6

0.7

0.8

0.9

1

1

L2-05

Undervoltage Detection Level (Uv1)

190

190

190

190

190

190

190

L8-02

Overheat Alarm Level

°C

80

80

105

105

110

110

115

L8-06

Input Phase Detection Level

16.0

21.0

15.0

18.0

22.0

23.0

24.0

L8-09

Output Ground Fault Detection Selection

0

0

0

0

0

0

1

L8-38

Carrier Frequency Reduction

2

2

2

2

2

2

2

No.

Name

Unit

Default Settings

Bypass Model Z1B1

D088

D114

D143

D169

D211

D273

o2-04

Drive Model Selection

Hex.

70

72

73

74

75

76

b3-04

V/f Gain during Speed Search

%

100

80

80

80

80

80

b3-06

Output Current 1 during Speed Search

0.5

0.5

0.5

0.5

0.5

0.7

b3-08

Current Control Gain during Speed Search (Speed

Estimation Type)

0.50

0.50

0.50

0.50

0.50

0.50

b3-11

Speed Search Method Switching Level (Speed

Estimation Type)

5.0

5.0

5.0

5.0

5.0

5.0

C6-02

Carrier Frequency Selection

2

2

2

2

2

2

E2-01

Motor Rated Current

A

88

114

143

169

211

273

E2-03

Motor No-Load Current

A

18.5

21.9

38.2

44.0

45.6

72.0

L2-03

Momentary Power Loss Minimum Baseblock Time

s

1

1.1

1.1

1.2

1.3

1.5

L2-05

Undervoltage Detection Level (Uv1)

190

190

190

190

190

190

L8-02

Overheat Alarm Level

°C

115

115

109

109

109

109

L8-06

Input Phase Detection Level

24.0

25.0

28.0

26.0

28.0

28.0

L8-09

Output Ground Fault Detection Selection

1

1

1

1

1

1

L8-38

Carrier Frequency Reduction

2

2

2

2

2

2

B.15 Defaults by Drive Model

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

351