Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 245

Advertising
background image

Loose wiring in the drive input power terminals

• Ensure the terminals have been properly tightened.
Apply the tightening torque to the terminals as specified.

Refer to Wire Gauge and Tightening

Torque Specifications on page 62

.

There is a problem with the drive input power

voltage

• Check the voltage.
• Lower the voltage of the drive input power so that it is within the limits listed in the specifications.

Drive internal circuitry is worn

• Check the maintenance time for the capacitors (U4-05).
• Replace either the control board or the entire drive if U4-05 exceeds 90%. For instructions on

replacing the control board, contact Yaskawa or your nearest sales representative.

The drive input power transformer is too small and

voltage drops when the power is switched on

• Check for an alarm when the magnetic contactor, line breaker, and leakage breaker are closed.
• Check the capacity of the drive input power transformer.

Air inside the drive is too hot

Check the temperature inside the drive.

The CHARGE light is broken or disconnected

Replace either the control board or the entire drive. For instructions on replacing the control board,

contact Yaskawa or your nearest sales representative.

HOA Keypad Display

Minor Fault Name

voF

Output Voltage Detection Fault
There is a problem with the output voltage.

Cause

Possible Solutions

Hardware is damaged

Replace either the control board or the entire drive. For instructions on replacing the control board,

contact Yaskawa or your nearest sales representative.

HOA Keypad Display

Minor Fault Name

WrUn

Waiting for Run
A Run command has been issued and the drive is waiting to begin running the motor.

Cause

Possible Solutions

After a Run command has been entered, the drive

must wait for the time set to b1-11 to pass before

it can begin to operate the motor

This is not an error.

6.5 Alarm Detection

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

245

6

Diagnostics & Troubleshooting

Advertising