A

B

C

D

A

A

A – Sealing nut
B – Clamping claw

C – Sealing insert
D – Cable gland body

Figure 7.29 Cooling Fan Cable Gland: 4A0124

7.

Pull the clamp claw and sealing nut insert from the gland body and separate the pieces.

C

A

B

A – Clamping claw
B – Sealing insert

C – Opening

Figure 7.30 Separate the Clamping Claw and Sealing Insert: 4A0124

8.

Pull apart the opening on the sealing insert then remove it from the wiring. Slide the sealing nut and clamping claw

off the power lines.

7.5 Drive Cooling Fans

284

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual