A – Fan unit
B – Ground cables

C – Fan cables
D – Relay connectors

Figure 7.50 Cooling Fan Replacement: 4A0302

2.

Pull out the two relay connectors and loosen the ground cable caps to remove the fan cable.

A

C

C

B

D

D

B

A – Relay connectors
B – Caps

C – Ground cables
D – Remove the fan cables

Figure 7.51 Remove the Relay Connector and Loosen the Cable Ground: 4A0302

3.

Remove the screws holding the cooling fan unit in place and slide the fan unit out of the drive.

Figure 7.52 Remove the Cooling Fan Unit: 4A0302

4.

Remove the fan guards and replace the cooling fans.

7.5 Drive Cooling Fans