Refer to minor, For a list of alarm codes, Minor faults and alarms – Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 223: Operation errors, Auto-tuning errors

Advertising
background image

n

Minor Faults and Alarms

Refer to

Table 6.5

for an overview of possible alarm codes. Conditions such as overvoltages can trip faults and alarms. It is

important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. A fault (not an alarm) is

present if the ALM LED lights without blinking.

Refer to Faults on page 222

for information on fault codes.

Table 6.5 Minor Fault and Alarm Displays

HOA

Keypad

Display

Name

Page

AL02

BAS Interlock Open

239

AL03

Smoke Purge in Bypass

239

AL04

Smoke Purge in Drive

239

AL13

Loss of Load

239

AL14

Serial Communications Fault

239

AL16

<2>

Input Phase Rotation

240

bAT

HOA Keypad Battery Voltage Low

224

bb

Drive Baseblock

240

bUS

Option Card Communications Error

240

CE

MEMOBUS/Modbus Communication Error

240

CrST

Cannot Reset

241

EF

Run Command Input Error

241

EF0

Option Card External Fault

241

FAn

Internal Fan Fault

226

FbH

Excessive PI Feedback

241

FbL

PI Feedback Loss

241

Fn1

External Fan Fault

230

inTLK

<1>

Interlock Open

242

HOA

Keypad

Display

Name

Page

LT-1

Cooling Fan Maintenance Time

242

LT-2

Capacitor Maintenance Time

242

LT-3

Soft Charge Bypass Relay Maintenance Time

242

oH

Heatsink Overheat

243

oH2

Drive Overheat

243

oH3

Motor Overheat

243

oL3

Overtorque 1

243

ov

Overvoltage

243

PASS

MEMOBUS/Modbus Test Mode Complete

244

SAFE

Customer Safety

244

SE

MEMOBUS/Modbus Test Mode Fault

244

TdE

Time Data Error

236

TIM

Time Not Set

236

UL3

Undertorque 1

244

UL6

Undertorque 6

244

Uv

Undervoltage

244

voF

Output Voltage Detection Fault

245

WrUn

Waiting for Run

245

<1> ALM LED will not blink.
<2> Available in bypass controller software versions VST800298 and later.

n

Operation Errors

Table 6.6 Operation Error Displays

HOA

Keypad

Display

Name

Page

oPE01

Drive Unit Setting Error

246

oPE02

Parameter Setting Range Error

246

oPE03

Multi-Function Input Setting Error

246

oPE05

Run Command Selection Error

247

oPE07

Multi-Function Analog Input Selection Error

247

HOA

Keypad

Display

Name

Page

oPE09

PI Control Selection Error

247

oPE10

V/f Data Setting Error

247

oPE11

Carrier Frequency Setting Error

247

oPE28

Sequence Timer Error

248

n

Auto-Tuning Errors

Table 6.7 Auto-Tuning Error Displays

HOA

Keypad

Display

Name

Page

End3

Rated Current Setting Alarm

249

End4

Adjusted Slip Value Fell Below Lower Limit

249

End5

Resistance Between Lines Error

249

End7

No-Load Current Alarm

249

Er-01

Motor Data Error

249

Er-02

Alarm

249

HOA

Keypad

Display

Name

Page

Er-03

OFF Button Input

250

Er-04

Line-to-Line Resistance Error

250

Er-05

No-Load Current Error

250

Er-08

Rated Slip Error

250

Er-09

Acceleration Error

250

Er-12

Current Detection Error

250

6.3 Drive Alarms, Faults, and Errors

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

223

6

Diagnostics & Troubleshooting

Advertising