Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 289

Advertising
background image

Figure 7.41 Remove the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240

4.

Remove the fan guards and replace the cooling fans.

A

B

A – Fan guards

B – Cooling fans

Figure 7.42 Cooling Fan Disassembly: 2A0143 to 2A0273, 4A0156 to 4A0240

n

Installing the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240

1.

Reverse the procedure to reinstall the cooling fan unit.

Note:

Do not pinch the fan cable between parts when reassembling the fan unit.

Figure 7.43 Insert the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240

2.

Reattach the covers.

3.

Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.

7.5 Drive Cooling Fans

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual

289

7

Periodic Inspection & Maintenance

Advertising