B.15 defaults by drive model – Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 352

Advertising
background image

Table B.5 480 V Default Settings by Model Selection

No.

Name

Unit

Default Settings

Bypass Model Z1B1

B001

B002

B003

B004

B007

B011

B014

B021

B027

o2-04

Drive Model Selection

Hex.

94

96

98

99

9A

9C

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

b3-06

Output Current 1 during Speed Search

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Current Control Gain during Speed Search (Speed

Estimation Type)

0.50

0.50

0.50

0.50

0.50

0.50

b3-11

Speed Search Method Switching Level (Speed

Estimation Type)

5.0

5.0

5.0

5.0

5.0

5.0

C6-02

Carrier Frequency Selection

2

2

2

2

2

2

E2-01

Motor Rated Current

A

4.80

7.60

11.00

14.00

21.0

27.0

E2-03

Motor No-Load Current

A

1.5

2.3

2.6

4

5.6

7.6

L2-03

Momentary Power Loss Minimum Baseblock

Time

s

0.5

0.6

0.7

0.8

0.9

1.0

L2-05

Undervoltage Detection Level (Uv1)

380

380

380

380

380

380

L8-02

Overheat Alarm Level

°C

75

75

75

95

95

95

L8-06

Input Phase Detection Level

14.0

15.0

17.0

24.0

27.0

25.0

L8-09

Output Ground Fault Detection Selection

0

0

0

0

0

0

L8-38

Carrier Frequency Reduction

2

2

2

2

2

2

No.

Name

Unit

Default Settings

Bypass Model Z1B1

B034

B040

B52L

B052

B065

B077

B096

o2-04

Drive Model Selection

Hex.

9D

9E

9F

or

(B0)

<1>

9F

or

(B0)

<1>

A1

or

(B1)

<2>

A2

or

(B2)

<3>

A3

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

100

80

b3-06

Output Current 1 during Speed Search

0.5

0.5

0.5

0.5

0.5

0.5

0.5

b3-08

Current Control Gain during Speed

Search (Speed Estimation Type)

0.50

0.50

0.50

0.50

0.50

0.50

0.50

b3-11

Speed Search Method Switching Level

(Speed Estimation Type)

5.0

5.0

5.0

5.0

5.0

5.0

5.0

C6-02

Carrier Frequency Selection

2

2

2

2

2

2

2

E2-01

Motor Rated Current

A

34.0

40.0

52.0

52.0

65.0

77.0

96.0

E2-03

Motor No-Load Current

A

7.8

9.2

10.9

10.9

19.1

22

24

L2-03

Momentary Power Loss Minimum

Baseblock Time

s

1.0

1.0

1.1

1.1

1.1

1.2

1.2

L2-05

Undervoltage Detection Level (Uv1)

380

380

380

380

380

380

380

L8-02

Overheat Alarm Level

°C

100

100

102

102

102

102

102

L8-06

Input Phase Detection Level

30.0

24.0

24.0

24.0

24.0

24.0

25.0

L8-09

Output Ground Fault Detection

Selection

0

0

1

1

1

1

1

L8-38

Carrier Frequency Reduction

2

2

2

2

2

2

2

<1> Set o2-04 to B0 for Z1000 chassis drives with Rev: B in the nameplate model field.
<2> Set o2-04 to B1 for Z1000 chassis drives with Rev: B in the nameplate model field.
<3> Set o2-04 to B2 for Z1000 chassis drives with Rev: B in the nameplate model field.

B.15 Defaults by Drive Model

352

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual