5.6 Commands

■■■■■■■■■■■■■■■■■■■■■■

932

■■■■■■■■

tiamo 2.3 (for Process Analysis)

the aid of a CALC command according to the following formula (

ρ= den-

sity in g/mL):

Caution

The values for the axis intercept E(0), the slope s and the concentration
c

A

can only be iteratively recalculated out of voltages U

i

measured for

the sample and the spiked solutions and the known concentration of
the standard which requires a lot of effort because it is about an equa-
tion system with 3 unknowns. At least, the concentration c

S

is easily

recalculable with the values for E(0), U

S

and s calculated by tiamo (see

following example).

Example

Parameters
Concentration of the standard addition solution = 1000 ppm
Volume of the standard addition solution V

add

= 10 mL

Sample size V

S

= 10 mL

Measured data

dV

(mL)

U

(mV)

dU

(mV)

Sam-
ple

59.8

Incre-
ment
1

0.310

39.9

-20.0

Incre-
ment
2

0.705

19.9

-20.0

Incre-
ment
3

1.750

-1.1

-21.0

Results
E(0) = 129.7
s = -61.5
c(F

-

) = 27.4 ppm

Recalculation
c

A

= 10

^((59.8 − 129.7) / -61.5) = 13.696

c(F

-

) = (10 + 10) / 10 * 13.696 = 27.39 ppm