Cmc event messages, Cmc8501, Cmc8502 – Dell PowerEdge VRTX User Manual

Page 105: 7 cmc event messages

Advertising
background image

7

CMC Event Messages

CMC8501

Message

Chassis Group Leader has synchronized this members configuration.

Detailed
Description

Multi Chassis Management feature on CMC allows for pushing the lead chassis configuration
data to its members. This message appears in the members log when the configuration data is
successfully synchronized with the Chassis group leaders configuration data.

Recommended
Response Action

No response action required.

Category

Configuration

SubCategory

CMC = Chassis Management Controller

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8502

Message

Unable to access the IPv6 information of the server.

Detailed
Description

CMC is unable to access the specified servers IPv6 information. Unable to display the specified
servers Launch iDRAC link on the CMC Web interface.

Recommended
Response Action

Enable IPv6 for the specified server using the CMC command line or CMC Web GUI interface,
so that the link to launch iDRAC is displayed on the CMC Web interface. For the command line
options or navigation for Web intereface, see the Trobleshooting section in the CMC Users
Guide.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

105