arg3 =

priority number

Detailed
Description

This situation occurs if the iDRAC is found to be turned off after power allocation information is
sent by the CMC or if the communications between the CMC and iDRAC is non functional.

Recommended
Response Action

Perform a Virtual Reseat of the component identified in the message. Using the CMC Web UI,
go to Chassis Overview > Troubleshooting > Reset Components, and then select slot for the
component identified in the message and apply the Virtual Reseat.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8555

Message

Chassis Management Controller unable to turn on

arg1

-

arg2

at priority

arg3

because of

insufficeint power. Minimum power needed is

arg4

AC Watt, but only

arg5

AC Watt is available.

Arguments

arg1 =

component name

arg2 =

slot number

arg3 =

priority number

arg4 =

min power

arg5 =

avaialble power

Detailed
Description

The request to turn on the component identified in the message was not successful because
insuffficient power is available at the identified priority for the component.

Recommended
Response Action

Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 2 (Warning)

Trap/EventID

8418

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

574