Asr0003, Asr0008 – Dell PowerEdge VRTX User Manual

Page 61

Advertising
background image

ASR0003

Message

The watchdog timer power cycled the system.

Detailed
Description

The operating system or an application failed to communicate to the baseboard management
controller (BMC). The system powered cycled per the configured setting.

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

ASR0008

Message

The watchdog timer interrupt was initiated.

Detailed
Description

The operating system or an application failed to communicate to the baseboard management
controller (BMC) within the timeout period. The BMC invoked a system interrupt. (IPMI sensor
type code 23h - offset 00h)

Recommended
Response Action

Check the operating system, application, hardware, and system event log for exception events.

Category

System Health

SubCategory

ASR = Auto Sys Reset

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

61

Advertising