IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8582

Message

Chassis Management Controller is unable to turn on server-

arg1

because Max Power

Conservation Mode is enabled.

Arguments

arg1 =

slot number

Detailed
Description

Unable to turn on the server identified in the message because the Max Power Conservation
Mode (MPCM) is enabled. After MPCM is enabled, the chassis will be in power conservation
mode and the CMC cannot process any further server power on operation requests.

Recommended
Response Action

Disable the Max Power Conservation Mode and retry the operation.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

None

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PWR8583

Message

Chassis Management Controller is unable to turn on server-

arg1

because unacknowledged

110V PSUs are present.

Arguments

arg1 =

slot number

Detailed
Description

To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If the feature
is not enabled, the server turn-on operation will not be processed.

Recommended
Response Action

On the Power Configuration page, in the Web UI, select the Allow 110VAC Operation for power
supplies and retry the operation. Using the RACADM utility, run the following command,
"racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1".