Vdr91, Vdr92 – Dell PowerEdge VRTX User Manual
Page 887

Recommended
Response Action
Replace the missing or failed physical disk.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR91
Message
Consistency check for
arg1
has detected multiple uncorrectable medium errors.
Arguments
•
arg1 =
virtual disk
Detailed
Description
This message occurs if there are medium errors in the physical drives.
Recommended
Response Action
Replace the failed drives.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR92
Message
Consistency check for
arg1
has completed with uncorrectable errors.
Arguments
•
arg1 =
virtual disk
887